Annual maintenance (By authorized maintenance personnel only)
1 . Check correct functioning of the emergency stop switch
2 . Check all safety devices (correct functioning of light barriers, protective trip switch)
3 . The electrical cabinet should be checked during the annual maintenance performed on the MultiCam CNC machine
4 . The belts on all transmissions and Lead Screw Z-nuts be replaced every other year.
5 . Operators should not use compressed air when cleaning out the cabinet as this action may cause unwanted particles to short out some of the electrical components.